railway RRB JE (CBT I + CBT II) Mock Test 2024 Electrical Machines DC Generators Types of DC Generators
A given shunt generator delivers 430 A at 240 V and the resistance of the shunt field and armature are 60 Ω and 0.02 Ω respectively. Calculate the armature voltage drop.
1
12.68 V
2
15 V
3
10 V
4
8.68 V