engineering recuitment GATE EE 2023-24 Test Series Electrical Machines Single Phase Motor and Special Machines Single Phase Motor Starting
The resistance and reactance of the main winding of a 50 Hz single phase induction motor are 1 Ω and √3 Ω, respectively. The motor is capacitor start motor. If the resistance and the reactance of the auxiliary winding are 1 Ω and 1.2 Ω respectively, then the external capacitance (in mF) to be added to the auxiliary winding to get the maximum starting torque is ________
Enter numerical value using the virtual keypad. Round off where necessary.