engineering recuitment GATE EE 2023-24 Test Series Electrical Machines Alternator and Synchronous Motors Salient Pole Alternator Operation
The generator is connected to an infinite bus through a reactance of 0.15 pu. The excitation voltage is 1.5 pu and the infinite bus voltage is maintained at 1.1 pu, direct axis synchronous reactance of 0.85 pu and quadrature axis synchronous reactance of 0.65 pu. For a power angle of 30°, the active power supplied to the bus will be ______ (in pu)
Enter numerical value using the virtual keypad. Round off where necessary.